Rack Mount Installation of Terra (Compact) and Strato C

Single Unit Installation

  1. Place the Terra (compact) or Strato C Movie Player upside down on a soft, clean, and slightly elevated surface.

  2. Remove and keep the three black screws visible on the bottom of the unit.
     

 
  1. Place the rack shelf centered over the unit and align the front of the unit and the rack mount as required by the installation.  In the frontmost position the player face will protrude by ¾” (recommended). In the rearmost position, the face of the player is flush with the front of the rack ears. Install the center saved screw to set this position. Install the other two screws where they line up with the rear holes. This will vary based on the model being installed.
     

Diagram, engineering drawing  Description automatically generated
 
 
  1. Place the single-opening fascia in front of the unit and carefully slide into position.
     

Diagram, engineering drawing  Description automatically generated
 
  1. The bottom flange on the fascia will go on the outside of the shelf. This panel is not firmly attached until the shelf is installed in the rack.
     

Diagram, engineering drawing  Description automatically generated
 
 
  1. While firmly holding the fascia to the rack shelf, flip the assembly over.  It is ready to install in the rack.
     

Diagram, engineering drawing  Description automatically generated

 

Dual Unit Installation

  1. Place two units upside-down on a soft, clean and slightly elevated surface. This can be any combination of Terra (compact) Servers or Strato C Movie Players.

  2. Remove and keep the three black screws visible on the bottom of each unit.
     

Diagram, engineering drawing  Description automatically generated
 
  1. Place the rack shelf over the units and align the front of the unit and the rack mount as required by the installation.  In the frontmost position the units face will protrude by ¾” (recommended). In the rearmost position, the face of the unit is flush with the front of the rack ears. Install the center saved black screw to set this position. Install the other two screws where they line up with the rear holes. This will vary based on the model being installed.
     

Diagram, engineering drawing  Description automatically generated
 
  1. Place the dual-opening fascia in front of the units and carefully slide into position.
     

Diagram  Description automatically generated
 
  1. The bottom flange on the fascia will go on the outside of the shelf. This panel is not firmly attached until the shelf is installed in the rack.
     

Diagram, engineering drawing  Description automatically generated
 
  1. While firmly holding the fascia to the rack shelf, flip the assembly over.  It is ready to install in the rack.
     

Diagram, engineering drawing  Description automatically generated

 

 